A0203 25D Four-Handle Advanced HIFU Machine with RF EMS

Product Name: A0203 25D Four-Handle Advanced HIFU Machine with RF EMS
Energy Type: High Intensity Focused Ultrasound (MMFU – Macro & Micro Focused Ultrasound)
Output Energy: 0.1~0.3J (0.1J adjustable)
Dot Spacing: 0.1~2mm (0.1mm adjustable)
Output Length: 5.0~25mm (5mm adjustable)
Power Supply: 100-240V 50Hz/60Hz
Product Weight: 45KG
Product Dimensions: 52*61*120cm
Probe Configuration: 1.5mm / 2.0mm / 3.0mm / 4.5mm / 6.0mm / 9.0mm / 13.0mm
Handle Configuration: Four-Handle Design (4 probes can be connected simultaneously)
Operating handle: 15RS, 18RS, 25RS, 36RS
Patented Technology: 2.0mm ultra-thin eye probe (Clexis patented technology) / 5.5MHz
Temperature Control: Fat cell destruction ~50°C / Thermal coagulation effect 65-75°C
Language Support: Chinese/English/Russian/Portuguese/Spanish/French/German/Korean/Japanese/Italian

A0203 25D Four-Handle Advanced HIFU Machine with RF EMS

Third-generation MMFU Technology | Multi-depth Treatment System | Four-Handle Design for Enhanced Efficiency

Product Overview

The A0203 25D Four-Handle Advanced HIFU Machine with RF EMS represents the cutting edge of non-invasive aesthetic technology, featuring an advanced MMFU (Macro & Micro Focused Ultrasound) system. This third-generation device delivers precise ultrasonic energy to multiple tissue layers—from superficial epidermis to deep SMAS fascia and fat compartments—creating thermal coagulation zones that stimulate collagen regeneration while selectively destroying fat cells, all without harming surrounding tissues.

The innovative vertical design with four-handle capability allows practitioners to perform multi-depth treatments simultaneously or switch between probes seamlessly, significantly reducing treatment time and enhancing clinical outcomes. Featuring the advanced 25D handle and micro-pulse ultrasonic technology, it delivers precise and focused energy for maximum lifting, tightening, and contouring results.

Key Advantages

  1. Four-Handle Design – Connect four probes simultaneously for efficient multi-depth treatment; reduces procedure time by up to 40%

  2. MMFU Dual-focus Technology – Combines macro-focused ultrasound (8x larger focus point than ordinary HIFU) for safe fat cell destruction with micro-focused ultrasound for precise collagen stimulation

  3. Interchangeable Probes – Complete depth coverage: 1.5mm, 2.0mm, 3.0mm, 4.5mm, 6.0mm, 8.0mm, 8.0mm, 10.0mm, 13.0mm, 16.0mm, 18.0mm

  4. Patented 2.0mm Eye Probe – World-first ultra-thin probe with 5.5MHz frequency (Clexis patented technology) for safe and effective periorbital treatment

  5. Dual-temperature Technology – Selective fat destruction at ~50°C + thermal coagulation for collagen at 65-75°C

  6. Vertical Space-Saving Design – Compact footprint (52*61*120cm) ideal for clinics with limited space

  7. Multi-level Treatment Protocol – Systematic approach from shallow to deep or deep to shallow depending on treatment area

  8. Comprehensive Coverage – From delicate eye area to deep body contouring

Technical Specifications

ParameterDetails
ModelA0203 25D Four-Handle  HIFU Machine with RF EMS
Energy TypeHigh Intensity Focused Ultrasound (MMFU)
Output Energy0.1~0.3J (0.1J adjustable)
Dot Distance0.1~2mm (0.1mm adjustable)
Output Length5.0~25mm (5mm adjustable)
Power Supply100-240V, 50Hz/60Hz
Product Weight45KG
Dimensions52*61*120cm (Vertical Design)
Handle ConfigurationFour-Handle System (4 probes can be connected simultaneously)
Probe Depths1.5mm, 2.0mm, 3.0mm, 4.5mm, 6.0mm, 8.0mm, 9.0mm, 10.0mm, 13.0mm, 16.0mm, 18.0mm
Probe Shots10,000 shots per cartridge
Operating handle15RS, 18RS, 25RS, 36RS

Probe Applications & Specifications

HandleStandard CartridgeOptional CartridgeCartridge LifeFrequencyWorking Mode
25RS1.5 / 3.0 / 4.5 mm6.0 / 8.0 / 10.0 / 13.0 / 16.0 mm10,000 lines/cartridge1.5 / 3.0 mm: 5.5 MHz; 4.5 / 6.0 / 8.0 mm: 4 MHz; 10.0 / 13.0 / 16.0 mm: 2 MHzUp to 12 lines/shot; up to 24 dots/line; Dot & Line Mode
15RS1.5 / 2.0 / 3.0 / 4.5 mm6.0 / 9.0 / 13.0 mm10,000 shots/cartridge1.5 / 2.0 / 3.0 mm: 5.5 MHz; 4.5 / 6.0 mm: 4 MHz, 9.0 / 13.0 mm: 2 MHzUp to 24 dots/shot; Spot & Line Mode
36RS1.5 / 3.0 / 4.5 mm6.0 / 9.0 / 13.0 mm / Face Plasma10,000 circles/cartridge1.5 / 3.0 mm: 5.5 MHz; 4.5 / 6.0 mm: 4 MHz; 9.0 / 13.0 mm: 2 MHzCircular Mode; Spot & Continuous Circular Line Mode
18RS8.0 / 13.0 mm6.0 / 10.0 / 16.0 / 18.0 mm10,000 lines/circles per cartridge6.0 / 8.0 / 10.0 mm: 4 MHz; 13.0 / 16.0 / 18.0 mm: 2 MHzUp to 24 × 24 lines; up to 24 dots/row or line; Spot, Line & Circular Mode

Treatment Areas

Face & Neck:

  • Forehead

  • Periorbital area (eyebrows, eye bags, crow’s feet)

  • Cheeks

  • Nasolabial folds

  • Jawline

  • Mouth area

  • Neck/throat

Body:

  • Upper arms (butterfly sleeves)

  • Waist/Abdomen

  • Buttocks (mother’s buttocks)

  • Thighs (elephant legs)

  • Armpits

  • Chest/Shoulders

  • Double chin

  • Legs/Arms

Working Principle

The A0203 25D HIFU utilizes third-generation MMFU (Macro & Micro Focused Ultrasound) technology, which represents an evolution of the medical ultrasound technology originally developed for cancer treatment.

How it works:
The transducer generates high-energy ultrasound waves that penetrate the skin and converge at precise focal points within targeted tissue layers. At these focal points, the concentrated energy produces thermal effects:

  • Macro-focused ultrasound creates focus points 8x larger than ordinary HIFU, safely destroying fat cells at approximately 50°C without harming surrounding tissues

  • Micro-focused ultrasound delivers precise energy at 65-75°C to target layers (dermis, SMAS) creating thermal coagulation zones

  • These coagulation zones trigger immediate tissue contraction and stimulate long-term neocollagenesis and elastin production

  • Results continue to improve over 3-6 months as new collagen forms

The four-handle design allows practitioners to:

  • Treat multiple depths simultaneously (e.g., 4.5mm for SMAS + 3.0mm for dermis)

  • Switch between face and body probes without pausing

  • Reduce total treatment time by 30-40%

Safety Features & Precautions

Contraindications:

  • Pregnancy

  • Active infections or skin diseases in treatment area

  • Severe diabetes or autoimmune disorders

  • Pacemakers or metal implants in treatment area

  • Cancer patients

  • Recent cosmetic surgery in treatment area

Treatment Precautions:

  • Avoid direct treatment over nerves (supraorbital, cervical, marginal mandibular, ulnar)

  • Avoid breast tissue, clavicle, and implant areas

  • Adjust dot spacing to 10-15mm before treatment initiation

  • For multi-level nursing, follow proper sequence (shallow↔deep depending on area)

  • Patients must close eyes during periorbital treatment

  • Do not apply excessive pressure on delicate areas (neck, eyes)

  • Always perform a patch test on new patients

Recommended Treatment Protocol:

  1. Cleanse treatment area thoroughly

  2. Apply ultrasound gel

  3. Select appropriate probe and parameters based on treatment area

  4. Begin treatment following recommended depth sequence

  5. Post-treatment: Apply soothing cream, avoid extreme temperatures for 24-48 hours

  6. Schedule follow-up treatments every 4-6 weeks for optimal results

Package Includes

  • Main control unit (vertical design)

  • 4 Handpieces (four-handle system)

  • Standard probe set (configuration available upon request)

  • Foot control pedal

  • User manual with detailed protocols

  • Multi-language interface

  • 1-year warranty

Optional Accessories

  • Additional probe cartridges (all depths available)

  • Probe sterilization container

  • Treatment gel (bulk option)

  • Portable trolley (if mobility needed)

Languages Supported

Chinese / English / Russian / Portuguese / Spanish / French / German / Korean / Japanese / Italian

Clinical Results

Immediate Effects:

  • Visible skin tightening (10-20% improvement)

  • Lifted eyebrow and jawline

  • Reduced appearance of fine lines

Long-term Results (3-6 months):

  • Progressive collagen regeneration

  • Continued improvement in skin elasticity

  • Maximum lifting and contouring effect

  • Reduction in fat deposits in treated areas

Typical Treatment Schedule:

  • Initial course: 2-3 sessions, 4-6 weeks apart

  • Maintenance: 1-2 sessions per year

  • Session duration: 30-60 minutes depending on treatment area

Hot products